Wind Farm Fault Indicators

Features and Benefits
- Line-powered operation for longer life and limited maintenance (no batteries required)
- Current trip value up to 1500 A with delayed trip response time
- Remote display options that allow quick determination of indicator status without the need to open medium-voltage compartments
- Easy installation on separable connector components with capacitive test points
- For installation in transformers, switches, and junction boxes
- Units available that work with cold-shrink silicone medium- voltage terminations
- Auxiliary contact output option for connection to SCADA for remote monitoring

Wind turbine outputs are fed through a transformer and distributed overhead or underground to a collector substation. The voltage will then be stepped up by the collector substation transformer to the utility transmission voltage. A single fault can disable from one to an entire line of turbines.
SEL fault indicators help operations personnel quickly deter- mine the location of the fault, isolate the faulted section, and restore the balance of the wind farm.
Electrostatic Reset

- High-voltage ac electric field powers the ERL.
- ERL automatically resets upon restoration of system voltage.
- Inrush restraint feature prevents false tripping during recloser operations.
- Reflective red target (the largest display in the industry) is easy to spot, both at night and during the day.
- Zero maintenance: there is no battery to replace or monitor.
Test Point Reset (shown with remote display)

- Most economical solution for underground applications.
- Powered from voltage present at T-body test point.
- Easy to install on most brands of 600 A class elbows with capacitive test points.
- Automatically resets upon restoration of system voltage.
- Works independently of load current.
- Ideal for pad-mounted transformer and switchgear applications.
- Features remote display versions that eliminate the need to open an enclosure cabinet to determine indicator’s status.
- Allows access to the test point with simple removal of the fault indicator.
- Compatible with SCADA through the auxiliary contact option.
- Prevents false tripping due to adjacent phase effects with junction shield option.
Three-Phase Voltage Reset Device

- No batteries required.
- Voltage powered from BIP.
- No T-body capacitive test point required.
- Automatic reset after BIP voltage restoration.
- Operation is independent of load current.
- Up to 1500 A trip value (higher on request).
- Several remote display options available.
- Auxiliary contact option for SCADA compatibility.
CR—Current Reset

- Automatic reset upon restoration of load current.
- Closed-core design provides adjacent phase immunity.
- Available for single- and three-phase applications.
- Choose from BEACON™ LED, target, and combination displays, depending on your application and operating practices.
- Ideal for installation in pad-mounted equipment without elbow test points; install the fault indicator outside of the influence of the ground return path of the cable’s concentric neutral.
- Installation on low-voltage secondary lines is an ideal fault-finding solution in industrial environments.
- Choose the auxiliary contact option for SCADA compatibility.
- Fault-powered current reset models also available for low-load current applications. Please consult factory.
Contact the WECS New Construction Team at (760) 251-0040 ex2667